| Transmission Line |
Article Index for Transmission |
Articles about Transmission Line |
Website Links For Transmission |
Information AboutTransmission Line |
| CATEGORIES ABOUT TRANSMISSION LINE | |
| cables | |
| communication engineering | |
|
Components of transmission lines include Wire s, Coaxial Cable s, Dielectric slabs, Optical Fiber s, electric power lines, and Waveguide s. HISTORY Mathematical analysis of the behaviour of electrical transmission lines grew out of the work of James Clerk Maxwell , Lord Kelvin and Oliver Heaviside . In 1855 Lord Kelvin formulated a diffusion model of the current in a submarine cable. The model correctly predicted the poor performance of the 1858 trans-Atlantic Submarine Telegraph cable. In 1885 Heaviside published the first papers that described his analysis of propagation in cables and the modern form of the telegrapher's equations. Ernst Weber and Frederik Nebeker, ''The Evolution of Electrical Engineering'', IEEE Press, Piscataway, New Jersey USA, 1994 ISBN 0-7803-1066-7 TRANSMISSION LINE VS WIRE In many Electric Circuit s, the length of the wires connecting the components can for the most part be ignored. That is, the voltage on the wire at a given time can be assumed to be the same at all points. However, when the voltage changes in a time interval comparable to the time it takes for the signal to travel down the wire, the length becomes important and the wire must be treated as a transmission line. Stated another way, the length of the wire is important when the signal includes Frequency Components with corresponding Wavelength s comparable to the length of the wire. A common rule of thumb (justified in the input impedance section) is that the cable or wire should be treated as a transmission line if the length is greater than 1/100 of the wavelength. At this length the phase delay and the interference of any reflections on the line become important and can lead to unpredictable behavior in systems which have not been carefully designed using transmission line theory. THE FOUR TERMINAL MODEL Electronic Symbol for a transmission line.]] For the purposes of analysis, an electrical transmission line can be modelled as a two-port network (also called a quadrupole network), as follows: In the simplest case, the network is assumed to be linear (i.e. the Complex voltage across either port is proportional to the complex current flowing into it when there are no reflections), and the two ports are assumed to be interchangeable. If the transmission line is uniform along its length, then its behaviour is largely described by a single parameter called the '' Characteristic Impedance '', symbol Z0. This is the ratio of the complex voltage of a given wave to the complex current of the same wave at any point on the line. Typical values of Z0 are 50 or 75 Ohm s for a Coaxial Cable , about 100 ohms for a twisted pair of wires, and about 300 ohms for a common type of untwisted pair used in radio transmission. When sending power down a transmission line, it is usually desirable that as much power as possible will be absorbed by the load and as little as possible will be reflected back to the source. This can be ensured by making the source and load impedances equal to Z0, in which case the transmission line is said to be '' Matched ''. Some of the power that is fed into a transmission line is lost because of its resistance. This effect is called ''ohmic'' or ''resistive'' loss (see Ohmic Heating ). At high frequencies, another effect called ''dielectric loss'' becomes significant, adding to the losses caused by resistance. Dielectric loss is caused when the insulating material inside the transmission line absorbs energy from the alternating electric field and converts it to Heat (see Dielectric Heating ). The total loss of power in a transmission line is often specified in Decibel s per Metre , and usually depends on the frequency of the signal. The manufacturer often supplies a chart showing the loss in dB/m at a range of frequencies. A loss of 3 dB corresponds approximately to a halving of the power. High-frequency transmission lines can be defined as transmission lines that are designed to carry electromagnetic waves whose Wavelength s are shorter than or comparable to the length of the line. Under these conditions, the approximations useful for calculations at lower frequencies are no longer accurate. This often occurs with Radio , Microwave and Optical signals, and with the signals found in high-speed Digital Circuit s. TELEGRAPHER'S EQUATIONS See Also: Telegraphers equations The Telegrapher's Equations (or just '''Telegraph Equations''') are a pair of linear differential equations which describe the Voltage and Current on an electrical transmission line with distance and time. They were developed by Oliver Heaviside who created the ''transmission line model'', and are based on Maxwell's Equations . The transmission line model represents the transmission line as an infinite series of two-port elementary components, each representing an infinitesimally short segment of the transmission line:
The model consists of an ''infinite series'' of the elements shown in the figure, and that the values of the components are specified ''per unit length'' so the picture of the component can be misleading. , , , and may also be functions of frequency. An alternative notation is to use , , and to emphasize that the values are derivatives with respect to length. The line voltage and the current can be expressed in the frequency domain as : : When the elements and are negligibly small the transmission line is considered as a lossless structure. In this hypothetical case, the model depends only on the and elements which greatly simplifies the analysis. For a lossless transmission line, the second order steady-state Telegrapher's equations are: : : These are Wave Equation s which have Plane Wave s with equal propagation speed in the forward and reverse directions as solutions. The physical significance of this is that electromagnetic waves propagate down transmission lines and in general, there is a reflected component that interferes with the original signal. These equations are fundamental to transmission line theory. If and are not neglected, the Telegrapher's equations become: : : where : and the characteristic impedance is: : The solutions for and are: : : The constants and must be determined from boundary conditions. For a voltage pulse , starting at and moving in the positive -direction, then the transmitted pulse at position can be obtained by computing the Fourier Transform, , of , attenuating each frequency component by , advancing its phase by , and taking the inverse Fourier Transform. The real and imaginary parts of can be computed as : : where Atan2 is the two-parameter arctangent, and : : For small losses and high frequencies, to first order in and one obtains : : Noting that an advance in phase by is equivalent to a time delay by , can be simply computed as : INPUT IMPEDANCE OF A TRANSMISSION LINE The Characteristic Impedance of a transmission line is the ratio of the amplitude of a single voltage wave to its current wave. Since most transmission lines also have a reflected wave, the characteristic impedance is generally '''not''' the impedance that is measured on the line. For a lossless transmission line, it can be shown that the impedance measured at a given position from the load impedance is : where is the wavenumber. For the special case where where n is an integer (meaning that the length of the line is a very close to a multiple of half a wavelength), the expression reduces to the load impedance so that for all . This includes the case when , meaning that the length of the transmission line is less than about 1/100 of the wavelength. The physical significance of this is that the transmission line can be ignored (i.e. treated as a wire) in either case. Another special case is when the load impedance is equal to the characteristic impedance of the line (i.e. the line is ''matched''), in which case the impedance reduces to the characteristic impedance of the line so that In calculating , the wavelength is generally different inside the transmission line to what it would be in free-space and the velocity constant of the material the transmission line is made of needs to be taken into account when doing such a calculation. PRACTICAL TYPES OF ELECTRICAL TRANSMISSION LINE Coaxial cable See Also: coaxial cable Coaxial lines confine the electromagnetic wave to the area inside the cable, between the center conductor and the shield. The transmission of energy in the line occurs totally through the dielectric inside the cable between the conductors. Coaxial lines can therefore be bent and twisted (subject to limits) without negative effects, and they can be strapped to conductive supports without inducing unwanted currents in them. In radio-frequency applications up to a few gigahertz, the wave propagates in the Transverse Electric And Magnetic Mode (TEM), which means that the electric and magnetic fields are both perpendicular to the direction of propagation. However, above a certain frequency called the cutoff frequency, the cable behaves as a Waveguide , and propagation switches to either a transverse electric (TE) or a transverse magnetic (TM) mode or a mixture of modes. This effect enables coaxial cables to be used at microwave frequencies, although they are not as efficient as the more expensive, purpose-built waveguides. The most common use for coaxial cables is for television and other signals with bandwidth of multiple Megahertz. In the middle 20th Century they carried Long Distance telephone connections. Microstrip See Also: microstrip A microstrip circuit uses a thin flat conductor which is Parallel to a Ground Plane . Microstrip can be made by having a strip of copper on one side of a Printed Circuit Board (PCB) or ceramic substrate while the other side is a continuous ground plane. The width of the strip, the thickness of the insulating layer (PCB or ceramic) and the Dielectric Constant of the insulating layer determine the characteristic impedance. Stripline Main article : Stripline A stripline circuit uses a flat strip of metal which is sandwiched between two parallel ground planes. The insulating material of the substrate forms a dielectric. The width of the strip, the thickness of the substrate and the relative permittivity of the substrate determine the characteristic impedance of the strip which is a transmission line. Balanced lines Lecher lines See Also: Lecher lines Lecher lines are a form of parallel conductor that can be used at UHF for creating resonant circuits. They are used at frequencies between HF / VHF where Lumped components are used, and UHF / SHF where resonant cavities are more practical. GENERAL APPLICATIONS OF TRANSMISSION LINES Transferring signals from one point to another Electrical transmission lines are very widely used to transmit high frequency signals over long or short distances with minimum power loss. One familiar example is the Down Lead from a TV or radio Aerial to the receiver. Pulse generation Transmission lines are also used as pulse generators. By charging the transmission line and then discharging it into a Resistive load, a rectangular pulse equal in length to twice the Electrical Length of the line can be obtained, although with half the voltage. A Blumlein Transmission Line is a related pulse forming device that overcomes this limitation. These are sometimes used as the Pulsed Energy sources for Radar Transmitters and other devices. Stub filters If a short-circuited or open-circuited transmission line is wired in parallel with a line used to transfer signals from point A to point B, then it will function as a filter. The method for making stubs is similar to the method for using Lecher lines for crude frequency measurement, but it is 'working backwards'. One method recommended in the RSGB 's radiocommunication handbook is to take an open-circuited length of transmission line wired in parallel with the feeder delivering signals from an aerial. By cutting the free end of the transmission line, a minimum in the strength of the signal observed at a receiver can be found. At this stage the stub filter will reject this frequency and the odd harmonics, but if the free end of the stub is shorted then the stub will become a filter rejecting the even harmonics. ACOUSTIC TRANSMISSION LINES See Also: Acoustic transmission lines SEE ALSO
REFERENCES ''Part of this article was derived from Federal Standard 1037C .''
EXTERNAL ARTICLES AND FURTHER READING
|
|
|