Wet Bulb Globe Temperature Article Index for
Wet
Website Links For
Wet
 

Information About

Wet Bulb Globe Temperature




WBGT=0.7T_w + 0.2T_g + 0.1T_d

Where

Indoors, or when solar radiation is negligible, the following formula is used:

WBGT=0.7T_w + 0.3T_g

The American Conference Of Governmental Industrial Hygienists publishes threshold limit values (TLVs) that have been adopted by many governments for use in the workplace. The process for determining the WBGT is also described in ISO 7243, Hot Environments - Estimation of the Heat Stress on Working Man, Based on the WBGT Index.

In hot areas, some US military installations display a flag to indicate the heat category based on the WBGT. The military publishes guidelines for water intake and physical activity level for acclimated and unacclimated individuals in different uniforms based on the heat category.

The WBGT index was developed by the United States Marine Corps at Parris Island in 1956 to reduce heat stress injuries in recruits and has been revised several times.

The Heat Index used by the National Weather Service and the Humidex used by the Meteorological Service Of Canada are also measures of perceived heat, but they do not account for solar radiation.


REFERENCES



SEE ALSO



EXTERNAL LINKS