| Power Cable |
Article Index for Power |
Website Links For Power |
Information AboutPower Cable |
| CATEGORIES ABOUT POWER CABLE | |
| fictional towns and cities in nebraska | |
|
HISTORY Early Telegraph systems were the first forms of electrical cabling but transmitted only small amounts of power. Gutta-percha insulation used for the first Transatlantic Cable s was unsuitable for building wiring use since gutta-percha deteriorated rapidly when exposed to air. The first power distribution system developed by Thomas Edison used copper rods, wrapped in jute and placed in rigid pipes filled with a bituminous compound. Although vulcanized rubber had been patented by Charles Goodyear in 1844, it was not applied to cable insulation until the 1880s that it was applied to power cables for lighting circuits. Rubber-insulated cable was used for 11,000 volt circuits in 1897 installed for the Niagara Falls power project. Oil-impregenated paper-insulated high voltage cables were commercially practical by 1895. During World War II several varieties of synthetic rubber, and Polyethylene insulation was applied to cables. --> CONSTRUCTION Modern power cables come in a variety of sizes,materials, and types, each particularly adapted to its uses. Large single insulated conductors are also called power cables in the trade. Conductors are usually made of copper or aluminum wires, or may be composite conductors with steel strands at their core. Conductors are usually stranded for flexibility, but small cables may use solid conductors. Conductors in a cable may be different sizes. Each conductor has its own electrical insulation. The cable may include uninsulated conductors used for the circuit neutral or for ground (earth) connection. The overall assembly may be round or flat. Filler strands may be added to the assembly to maintain its shape. Special purpose power cables for overhead or vertical use may have additional elements such as steel or Kevlar structural supports. For circuits operating at 2400 volts between conductors or more, a conductive shield surrounds each conductor. This equalizes electrical stress on the cable insulation. This technique was patented by Martin Hochstadter in 1916, and so the shield is sometimes called a Hochstadter shield. The individual conductor shields of a cable are connected to earth ground at one or both ends of each length of cable. Some power cables for outdoor overhead use may have no overall sheath. Other cables may have a plastic or metal sheath enclosing all the conductors. The materials for the sheath will be selected for the intended application, and may be specially resistant to water, oil, sunlight, underground conditions, chemical vapors, impact resistance, or high temperatures. Cables intended for underground use or direct burial in earth will have heavy plastic sheaths, or may be protected by a lead sheath. Where cables must run where exposed to impact damage, they are protected with flexible steel tape or wire armor, which may also be covered by a water resistant jacket. Cables for high-voltage (more than 65,000 volts) power distribution may be insulated with oil and paper, and are run in a semi-rigid steel pipe. The oil is kept under pressure to prevent formation of voids that would allow Partial Discharge s within the cable insulation. A hybrid cable will include conductors for control signals or may also include Optical Fibers for data. NAMED CABLE TYPES Common types of general-purpose cables used by Electrician s are defined by national or international regulations or codes. Commonly-used types of power cables are often known by a "shorthand" name. For example, NEC type ''NM-B'' (''Non-Metallic, variant B'') is a cable with a nonmetallic jacket. ''UF'' (''underground feeder'') is also nonmetallic but uses a moisture- and sunlight-resistant construction suitable for direct burial in the earth or in interiors in wet, dry, or corrosive locations. Type AC is a fabricated assembly of insulated conductors in a flexible metallic armor, made by twisting an interlocking metal strip around the conductors. ''BX'', an early Genericized Trademark of the General Electric company was used before and during WWII, designating a particular design of armored cable. In Canada, type TECK cable, with a flexible Aluminum or Steel armour and overall flame-retardent PVC jacket, is used in industry for wet or dry locations, run in tray or attached to building structure, above grade or buried in earth. A similar type of cable is designated type MC in the United States. Electrical power cables are often installed in raceways including Electrical Conduit , and cable trays, which may contain one or more conductors. Conduit may also be rigid or flexible, metallic or nonmetallic, and differentiation from cable may require some investigation of the contents at their termination. Mineral Insulated Copper Clad Cable (type ''MI'') is a fire-resistant cable using Magnesium Oxide as an insulator. It is used in demanding applications such as Fire Alarm s and Oil Refineries . AMPACITY The ampacity (current-carrying capacity) of any given cable is determined by the maximum heat that its insulation and jacket can withstand. The heat dissipating ability of the conductor is reduced by the electrical insulation around the conductor. If the current in the conductor is too high, the insulation would be damaged long before the conductor melts. Common standard ratings of cable insulation are 60, 90, or 105 degrees Celsius depending on the type of insulation. The ampacity for a cable is based on current, ambient temperature, and environmental conditions adjacent to the cable. In a long run of cable different conditions govern, and installation regulations specify that the most severe condition along the run governs the cable's rating. Cables run in wet or oily locations may carry a lower temperature rating than in a dry installation. Special calculations are necessary for multiple circuits in proximity in adjacent raceways. When multiple cables are bundled together, each contributes heat to the bundle and diminishes the amount of cooling air that can flow past the individual cables. The overall ampacity of the insulated conductors in a bundle of more than 3 must be derated, whether in a raceway or cable. Usually the de-rating factor is tabulated in the wiring regulations. FLEXIBLE CABLES All cables are flexible, which allows them to be shipped to installation sites on reels or drums. Where applications require a cable to be moved repeatedly, more flexible cables are used. Small cables are called "cords" or "flex". Flexible cords contain finer stranded conductors, rather than solid, and have insulation and sheaths that are engineered to withstand the forces of repeated flexing. Heavy duty flexible power cords such as feeding a mine face cutting machine are carefully engineered -- since their life is measurable in (6) weeks! See " Power Cord " and " Extension Cable " for further description of flexible power cables. Other types of flexible cable include Twisted Pair , extensible, Coaxial , Shielded , and Communication Cable . SEE ALSO
REFERENCES ''Underground Systems Reference Book'' , Edision Electric Institute, New York, 1957, no ISBN |
|
|